Fritz FL-14L CEMENT FLUID LOSS ADDITIVE
 

FLUID LOSS ADDITIVES
FL-7
FL-7L
FL-14
FL-14L
FL-17
FL-17L

GAS MIGRATION
FL-14
FL-14L
FL-17
FL-17L

DESCRIPTION - Fritz FL-14L is a non-aqueous suspension of FL-14 recommended for cementing systems to control the loss of filtrate from a cement slurry.

ADVANTAGES
• FL-14L is a non-retarding synthetic copolymer designed to control the loss of fluid from the slurry in porous environments.
• It is ideally suited for squeeze cementing particularly in coil tubing due to its non-gellation properties.
• In primary cementing, it functions as a gas migration control additive because of its non-gellation characteristics.
• It provides exceptional filtrate control when used with retarders at bottom hole circulating temperatures up to 350°F (177 C).

APPLICATION
• FL-14L may be used for fluid loss control in any API class of cement (A, C, G, or H).
• It may be used with other cement additives such as dispersants, silica flour, retarders, defoamers and weighting materials.
• FL-14L is not recommended for use in slurries with salt concentrations of 18% bww or greater.

PROPERTIES
• Off-White Liquid with Mineral Oil Odor
• Activity 41.7%
• Specific Gravity – 1.01
• Bulk Density – 8.39 lb./gal.
• Absolute Volume – 0.1192 gal./lb.
• Water Requirement – none
• Disperses in water
• Packaged in 5 gallon pails and 55 gallon drums
• Loading Rate – 0.08 to 0.27 gal./sk (0.30 to 1.02 L/sk)

TO DOWNLOAD AND PRINT PDF CLICK HERE


FL-14L FLUID LOSS TESTING
* ALL TESTING WAS PERFORMED WITH CLASS H CEMENT UNLESS OTHERWISE NOTED.
ADDITIVE
% BWC
WATER, GAL./SK
TEMP., ºF
ATM. VIS., Bc
RHEOLOGY (rpm)
FLUID LOSS, CC
THICKENING TIME, H:MM
COMMENTS
i
f
600
300
200
100
6
3
FL-14
0.3
5.0
80
5
6
129
70
48
27
4
3
78
FL-14
0.6
5.0
80
7
10
272
149
112
60
6
5
36
FL-14
0.6
9.06
80
15
12
151
91
69
44
5
5
42
8% BENTONITE BWC
FL-14
1.0
11.8
80
9
5
82
46
34
21
3
2
72
2% SODIUM METASILICATE BWC
FL-14
0.4
5.0
125
7
7
144
84
60
36
5
4
62
FL-14
0.5
5.0
125
9
9
215
123
88
53
7
5
48
FL-14
0.6
5.0
125
7
7
230
135
96
55
7
5
42
FL-14
0.6
5.0
125
9
9
32
NEAT
0.0
4.3
125
2:04
API 8,000 FT. CASING SCH. 5G
FL-14
0.3
4.3
125
8
9
210
124
90
53
7
6
90
FL-14
0.4
4.3
125
9
9
275
165
121
71
9
6
54
FL-14
0.5
4.3
125
10
11
330+
224
165
98
12
8
44
FL-14
O.6
4.3
125
2:53
API 8,000 FT. CASING SCH. 5G
FL-14
0.5
4.3
125
7
7
220
135
98
58
8
7
104
2% CALCIUM CHLORIDE BWC
FL-14
0.6
4.3
125
10
9
300+
161
118
70
10
7
66
2% CALCIUM CHLORIDE BWC
FL-14
0.8
5.0
180
12
11
212
125
91
53
6
4
32
FL-14
0.8
5.0
180
11
11
175
98
70
41
4
2
40
FL-14
0.6
4.3
180
9
7
137
77
51
32
4
3
112
SEA WATER
FL-14
0.8
4.3
180
13
7
209
122
89
51
5
3
44
SEA WATER
FL-14
0.6
5.0
125
9
9
236
141
104
61
7
5
70
CLASS G CEMENT
FL-14
0.8
5.0
180
12
9
254
155
115
67
7
5
56
CLASS G CEMENT

FL-14L ZERO STATIC GEL STRENGTH & GAS MIGRATION CONTROL TESTING

SLURRY COMPOSITION
TEMP., ºF
THICKENING TIME, H:MM
ZERO STATIC GEL STRENGTH, MINUTES
TRANSITION TIME, MINUTES
UCA 50 PSI, H:MM
UCA 500 PSI, H:MM
UCA 24 HR., PSI
H CEMENT+ RETARDER
140
53
333
8:10
9:35
2591
H CEMENT+ RETARDER+ 0.6% FL-14
140
4:45
545
5
9:39
10:51
2786
H CEMENT+ RETARDER
200
47
14
7:46
8;27
3175
H CEMENT+ RETARDER+ 0.6% FL-14
200
4:20
433
65
10:26
11:18
2660
H CEMENT+ RETARDER
250
67
62
5:45
6:31
2090
H CEMENT+ RETARDER+ 1.4% FL-14
250
4:19
241
67
6:47
7:44
1439

 


Fritz Corporate  |  Fritztile  |  Fritz Specialty  |  Fritz Bio  |  Fritz Pet  |  Fritz-Zyme