Fritz FL-17 CEMENT FLUID LOSS ADDITIVE
 

FLUID LOSS ADDITIVES
FL-7
FL-7L
FL-14
FL-14L
FL-17
FL-17L

GAS MIGRATION
FL-14
FL-14L
FL-17
FL-17L

DESCRIPTION - Fritz FL-17 is a powdered universal cement fluid loss and gas migration control additive recommended for blending with cement to control the loss of filtrate from a cement slurry.

ADVANTAGES
• FL-17 can be used in casing and liner cementing using fresh to saturated salt-water cement slurries.
• It is ideally suited for squeeze cementing in coil tubing due to its non-gellation properties.
• In primary cementing, it functions as a gas migration control additive because of its non-gellation characteristics.
• It provides exceptional filtrate control when used with retarders at bottom hole circulating temperatures up to 400°F (204 C).

APPLICATION
• Temperature range is 80°F – 400°F. (27 C to 204 C) See Low Temperature Data
• FL-17 may be used for fluid loss control in any API class of cement (A, C, G, or H).
• It may be used in fresh to saturated salt water slurries and is compatible with other additives such as dispersants, silica flour, retarders, defoamers and weighting materials.

PROPERTIES
• Brown Powder
• Specific Gravity – 1.47
• Solubility limited by resultant viscosity
• Water requirement – none
• pH – Neutral
• Packaged in 50 lb. bags
• Loading Rate – 0.2 to 3.0% bwc

TO DOWNLOAD AND PRINT PDF CLICK HERE

FL-17 FLUID LOSS TESTING
* ALL TESTING WAS PERFORMED WITH CLASS H CEMENT UNLESS OTHERWISE NOTED.

TEMP., ºF FL-17, % BWC WATER,% BWC SALT, % BWC #1 SILICA SAND RETARDER, % BWC ATM. VIS., Bc RHEOLOGY (rpm) FLUID LOSS, CC
i f 600 300 200 100 6 3
100
0.8%
38.0%
0%
0%
0.0%
13
15
330+
318
238
140
15
10
28
100
0.8%
38.0%
18%
0%
0.0%
12
15
330+
274
211
134
31
28
148
100
0.8%
38.0%
36%
0%
0.0%
14
16
330+
292
225
141
31
25
202
180
0.3%
38.0%
36%
0%
0.0%
Gelled
180
0.5%
38.0%
36%
0%
0.0%
11
8
226
133
96
57
11
10
539
180
0.8%
38.0%
36%
0%
0.0%
10
10
282
169
123
71
8
6
120
180
0.8%
38.0%
0%
0%
0.1%
17
20
330+
330+
305
214
91
88
52
180
0.8%
38.0%
18%
0%
0.1%
11
6
203
107
73
39
4
3
41
180
0.8%
38.0%
36%
0%
0.1%
13
7
235
142
103
60
6
5
38
180
0.3%
38.0%
0%
35%
0.5%
11
9
212
112
78
40
5
4
64
180
0.5%
38.0%
0%
35%
0.5%
11
10
276
160
113
60
5
4
38
180
0.8%
38.0%
0%
35%
0.5%
20
14
330+
315
220
121
10
5
22
180
0.3%
38.0%
18%
35%
0.5%
10
9
206
105
71
37
4
3
92
180
0.5%
38.0%
18%
35%
0.5%
14
10
255
131
90
47
4
3
38
180
0.8%
38.0%
18%
35%
0.5%
20
12
330+
217
154
83
7
4
29
180
0.3%
38.0%
36%
35%
0.5%
10
9
235
115
76
41
4
3
80
180
0.5%
38.0%
36%
35%
0.5%
12
9
260
127
90
48
5
4
42
180
0.8%
38.0%
36%
35%
0.5%
20
11
330+
196
139
76
6
4
23
245
0.3%
38.0%
0%
35%
0.5%
11
10
276
160
113
60
5
4
42
245
0.5%
38.0%
0%
35%
0.5%
11
10
276
160
113
60
5
4
19
245
0.8%
38.0%
18%
35%
0.5%
14
10
255
131
90
47
4
3
43
245
0.5%
38.0%
18%
35%
0.5%
20
12
330+
217
154
83
7
4
25
245
0.8%
38.0%
18%
35%
0.5%
21
10
330+
205
146
83
7
5
18
245
1.5%
38.0%
36%
35%
0.5%
12
9
260
127
90
48
5
4
46
245
0.5%
38.0%
36%
35%
0.5%
20
11
330+
196
139
76
6
4
28
308
1.5%
47.9%
0%
35%
1.5%
19
10
330+
173
121
65
6
3
88
308
1.5%
41.7%
18%
35%
1.5%
25
12
330+
208
146
85
7
4
30
308
1.0%
41.7%
36%
35%
1.0%
15
11
330+
330+
226
137
8
5
26
308
1.5%
41.7%
36%
35%
1.0%
15
12
330+
231
140
12
7
22

FL-17 FLUID LOSS TESTING
* ALL TESTING WAS PERFORMED WITH CLASS H CEMENT UNLESS OTHERWISE NOTED.

ADDITIVE
% BWC
WATER, GAL./SK
TEMP., ºF
ATM. VIS., Bc
RHEOLOGY (rpm)
FLUID LOSS, CC
THICKENING TIME, H:MM
COMMENTS
i
f
600
300
200
100
6
3
FL-17
0.3
4.3
80
6
7
161
92
64
35
4
3
224
FL-17
0.5
4.3
80
8
9
242
143
101
56
6
3
57
FL-17
0.7
4.3
80
8
11
300+
182
129
71
6
4
34
FL-17
1.0
4.3
80
11
14
300+
294
211
115
9
6
19
NEAT
0.0
4.3
125
2:04
API 8,000 FT. CASING
SCH. 5G
FL-17
0.5
4.3
125
7
7
169
101
73
41
5
3
100
FL-17
0.6
4.3
125
3:51
API 8,000 FT. CASING
SCH. 5G
FL-17
0.8
4.3
125
9
8
277
165
119
67
6
4
38
FL-17
1.0
4.3
125
8
11
300+
213
153
85
7
52
28
FL-17
1.0
4.3
180
9
7
176
90
61
32
3
2
34
10% SALT WATER; 0.2% FR-1 BWC
FL-17
1.0
4.3
180
10
7
161
84
58
30
3
2
34
18% SALT WATER; 0.2% FR-1 BWC
FL-17
1.0
4.3
180
12
8
162
107
77
42
4
2
32
SATURATED SALT WATER,
0.2% FR-1 BWC

FL-17 ZERO STATIC GEL STRENGTH & GAS MIGRATION CONTROL TESTING

SLURRY COMPOSITION
TEMP., ºF
THICKENING TIME, H:MM
ZERO STATIC GEL STRENGTH, MINUTES
TRANSITION TIME, MINUTES
UCA 50 PSI, H:MM
UCA 500 PSI, H:MM
UCA 24 HR., PSI
H CEMENT+ RETARDER
140
27
195
8:00
9:05
3206
H CEMENT+ RETARDER+ 0.6% FL-17
140
3:45
372
22
4:28
5:50
2669
H CEMENT+ RETARDER
200
47
14
4:14
4:56
3212
H CEMENT+ RETARDER+ 0.6% FL-17
200
3:30
144
32
3:25
3:59
3456
H CEMENT+ RETARDER
250
67
62
3:16
4:04
2154
H CEMENT+ RETARDER+ 1.4% FL-17
250
3:39
152
27
3:47
4:35
1878

FL-17 LOW TEMPERATURE TESTING

SLURRY DESIGN
ATMOSPHERIC CONSISTOMETER
RHEOLOGY DATA
CEMENT
JOPPA CLASS H
INITIAL
7
RPM
READING
FL-17
0.6% bwc
FINAL
8
600
247
CaCl2
1% bwc
300
144
WATER
40% bwc
UCA DATA
200
103
TEMPERATURE
80ºF
50 PSI @
3:54
100
57
2500 PSI @
24:00
6
5
FLUID LOSS
38 cc
3641 PSI @
48:00
3