DESCRIPTION - FRITZ PCR-4L is a liquid cement retarder and retarder intensifier used to
control the thickening time of a cement slurry.
ADVANTAGES
• PCR-4L is a 40% liquid that is added to the mixing water before slurrying with cement.
• It may be used to control the setting of a slurry for bottom hole circulating temperatures
from 220ºF (104 C) to 430ºF. (221 C)
APPLICATION
• Its primary application is as a retarder intensifier for use with Fritz PCR-3.
• PCR-4L may be used for retarding any API class of cement (A, C, G or H).
• It may be used with other cement additives such as fluid loss additives, silica flour,
dispersants, defoamers and weighting materials.
PROPERTIES
• Clear Liquid (40% solution)
• Specific Gravity – 1.20
• Bulk Density – 10.00 lb./gal.
• Absolute Volume – 0.1000 gal./lb.
• Packaged in 5 gallon pails and 55 gallon drums
• Water Requirements – none
• Loading Rate – 0.05 to 0.47 gal./sk (0.18 to 1.78 L/sk)
TO DOWNLOAD AND PRINT PDF CLICK HERE
CEMENT RETARDER INTENSIFIER TESTING
THICKENING TIME AND UCA DATA IN CLASS H CEMENT
CONTAINING SATURATED SALT, 35% #1 SILICA SAND AND 0.5% FLA
5.51 GAL./SK (20.9 L/SK); 17.0 LB./GAL. (2.0 KG/L)
PCR-4, % BWC |
PCR-3, % BWC |
THICKENING TIME, H:MM @ 285°F (140 C) |
0.3 |
0.65 |
3:15 |
0.3 |
0.55 |
3:30 |
0.2 |
0.55 |
2:24 |
0.3 |
0.55 |
3:36 |
0.4 |
0.55 |
4:29 |
THICKENING TIME AND UCA DATA IN CLASS H CEMENT
4.8 GAL./SK (18.2 L/SK); 15.9 LB./GAL. (1.9 KG/L)
PCR-4, % BWC |
PCR-3, % BWC |
THICKENING TIME, H:MM @ 270°F (132º C) |
0.0 |
0 |
0:40 |
0.2 |
0.7 |
2:59 |
0.4 |
0.7 |
7:19 |
0.6 |
0.7 |
7:56 |
THICKENING TIME AND UCA DATA IN CLASS H CEMENT
CONTAINING 35% #1 SILICA SAND AND 1.0% FLA
5.1 GAL./SK (19.3 L/SK); 17.0 LB./GAL. (2.0 KG/L)
PCR-4, % BWC |
PCR-3, % BWC |
THICKENING TIME, H:MM @ 370 °F (188º C) |
1.0 |
2.0 |
7:20 |
0.9 |
1.8 |
5:57 |
0.8 |
1.6 |
5:27 |
0.7 |
1.4 |
4:40 |
0.6 |
1.2 |
3:55 |
|