FRITZ ENCAP-A DELAYED RELEASE ACID
 

BREAKERS – ENCAPSULATED PRODUCTS
ENCAP-LE
ENCAP-LEX
ENCAP-LP
ENCAP-HP
ENCAP-BR
ENCAP-A
ENCAP-SBS

DESCRIPTION - EnCap-A is a delayed release acid used to slowly decrease the pH of high pH fluids. EnCap-A is encapsulated citric acid, a weak triprotic acid. EnCap-A is designed to be functional below 130°F.

ADVANTAGES
• EnCap-A allows a delayed pH decrease in the fluid.
• EnCap-A will insure the break of the borate crosslink by shifting the pH of the fluid below the pH needed to crosslink.
• EnCap-A allows conventional enzyme breakers to be used in high pH fluids; the lowering of the pH will activate the enzyme.
• EnCap-A will improve fracture conductivity in borate crosslinked fluids by aiding in breaking the formed filter cake and improving the clean-up of the proppant pack.

APPLICATION
• EnCap-A temperature limit is 130°F.
• In borate crosslinked fluids, EnCap-A is used as a crosslink breaker.
• EnCap-A is used as a conventional enzyme activator in high pH fluids. The pH of the fluid decreases to the active range of the enzyme, allowing the enzyme to break the guar based fluid. This application is typically limited to 125°F due to enzyme activity.
• EnCap-A will aid in proppant pack and filtercake clean-up in borate fracturing fluids. EnCap-A will concentrate in the fracture during fluid leak-off.

PROPERTIES
• Blue Granules
• Activity – 60 to 70%
• Specific Gravity – 1.59
• Bulk density – 60 lb./ft.3
• Partially soluble in water
• Final pH of 1% slurry in DI water – 2.2
• Release profile at 70°and 100°F see FIGURE 1
• Fluid pH profile at 75°F see FIGURE 2

TO DOWNLOAD AND PRINT PDF CLICK HERE



 

© 2004 FRITZ Industries, Inc. email: oilsales@fritzind.com LEGAL NOTICE